Transmitter/Controller Specifically designed for drinking and wastewater treatment plants, the MicroChem® is able to measure up to three of the following parameters: pH, ORP, Chlorine, Chlorine Dioxide, Conductivity, and 4-20 mA. The MicroChem® can be configured as an Analyzer/
Transmitter or a Controller. MicroChem® products are available packaged as a complete residual analyzer or as individual components allowing flexible configurations to meet specific customer needs.
Analyzer/Transmitter – The MicroChem® is capable of accepting signal(s) from up to three sensors representing a wide variety of measurements.
Controller – The MicroChem® can provide control of the measured parameter using a standard PID algorithm in conjunction with the sensor input signal, or as a PID Compound Loop controller utilizing the signal from the sensor and an optional 4-20 mA process flow signal. Two outputs are available from each channel card. One control output is available both as a 4-20 mA control signal or a pulse width modulation output. A second software configurable 4-20 mA output signal is available on each configured channel.
The MicroChem® CL1 Analyzer forms a complete system for measuring/controlling residual Chlorine. The amperometricbased three-electrode measure cell is designed to continuously analyze free or total chlorine over the range of 0-20 mg/L for drinking, wastewater, cooling water and other process water applications.
The measure cell is panel mounted and comes complete with a built-in pressure reducing valve to control sample inlet pressures up to 150 psi. A flow switch is included to alert the user in case of sample flow failure. A third electrode is utilized in the CL1 measure cell to further bias and stabilize the chlorine readings. Reagents are fed by a peristaltic pump assembly for up to a maximum 5 week supply of reagent(s). Water sample temperatures are measured, displayed and allow for automatic compensation of the chlorine levels.
The CL1 measure cell is constructed using corrosion-resistant materials. The measure cell electrodes are self-cleaning. The continuous action of PVC spheres inside the cell by a motor-driven striker insures electrodes are kept clean. Maintaining clean electrodes insures reliable readings from the analyzers. Each measure cell is supplied with sample and drain tubing as well as extra connectors to make installation easy at site. Optionally, an additional 12 mm electrode can be inserted into the sample inlet area allowing, for example, the capability to measure pH as well Click here for more information. A convenient wire tray is provided on the panel to organize the wire connections to the MicroChem® Instrument.